Filtered Sets

  1. Page 1 / 4

Your Selections

  1. Filtered Sets
Close
  1. Alaris Pump Module
    2477-0007

    Alaris Pump Module

    • Blood Set
    • 10 Per case
    Alaris Pump Module set Non-Vented Blood Set 180 Micron Filter Roller, 2 Slide Clamp(s) 1 SmartSite needle-free valve(s) 65" (below pumping segment) from 2-piece Male Luer Lock. Not Made with DEHP. 15 Drop L: 121 in L: 308 cm PV: 33 mL Fluid Path Sterile
  2. 20350ET / Extension Set
    20350ET

    Extension

    • Filtered Set
    Extension set Low Sorbing 0.2 Micron Filter (1.72 sq. in Low Protein Binding) Slide Clamp(s) 1 SmartSite needle-free valve(s) 6" from Texium Closed Male Luer. Not Made with DEHP. L: 20 in L: 51 cm PV: 6 mL Fluid Path Sterile
  3. 11532269 / Alaris Pump Module Set
    11532269

    Alaris Pump Module

    • Filtered Set
    • 20 Per case
    Alaris Pump Module set Low Sorbing Check Valve 0.2 Micron Filter (1.72 sq. in Low Protein Binding) Roller, Pinch Clamp(s) 2 SmartSite needle-free valve(s) 6
  4. 10010453 / Alaris Pump Module Set
    10010453

    Alaris Pump Module

    • Filtered Set
    • 20 Per case
    Alaris Pump Module set Low Sorbing 1.2 Micron Filter (1.72 sq. in Low Protein Binding) Roller, Pinch Clamp(s) 1 SmartSite needle-free valve(s) 6" (below pumping segment) from 2-piece Male Luer Lock. DEHP is not part of the material formulation. 20 Drop L: 115 in L: 291 cm PV: 26 mL Fluid Path Sterile
  5. Alaris Pump Module
    2432-0007

    Alaris Pump Module

    • Filtered Set
    • 20 Per case
    Alaris Pump Module set Check Valve 0.2 Micron Filter (1.72 sq. in Low Protein Binding) Roller, Slide Clamp(s) 3 SmartSite needle-free valve(s) 6", 18", 86" (1 above pumping segment and 2 below) from 2-piece Male Luer Lock. Not Made with DEHP. 20 Drop L: 117 in L: 297 cm PV: 28 mL Fluid Path Sterile
  6. 10014916 / Alaris Syringe Module Set
    10014916

    Alaris Syringe Module

    • Filtered Set
    • 100 Per case
    Alaris Syringe Module set Microbore Pressure Sensing Disc 0.2 Micron Small Volume Filter (0.25 sq. in Low Protein Binding) Slide Clamp(s) Fixed Male Luer Lock. Not Made with DEHP. L: 60 in L: 152 cm PV: 1 mL Fluid Path Sterile
  7. 42081E / Gravity Set
    42081E

    Gravity

    • Blood Set
    • 20 Per case
    Gravity set Non-Vented Blood Set 180 Micron Filter 3 Roller Clamp(s) 1 SmartSite needle-free valve(s) 9" from 2-piece Male Luer Lock. Not Made with DEHP. 15 Drop L: 104 in L: 264 cm PV: 30 mL Fluid Path Sterile
  8. 10010903 / Gravity Set
    10010903

    Gravity

    • Blood Set
    • 20 Per case
    Gravity set Non-Vented Blood Set 180 Micron Filter 3 Roller Clamp(s) 1 SmartSite needle-free valve(s) 9" from 2-piece Male Luer Lock With Pressure Pump. 15 Drop L: 105 in L: 264 cm PV: 67 mL Fluid Path Sterile
  9. Secondary with Bonded Texium
    4030B-07T

    Secondary

    • Low Sorbing Set
    Secondary set needle-free valve bag access port Low Sorbing 0.2 Micron Filter (1.72 sq. in Low Protein Binding) Roller, Pinch Clamp(s) Texium Closed Male Luer with hanger. Not Made with DEHP. 20 Drop L: 32 in L: 81 cm PV: 14 mL Fluid Path Sterile
  10. Alaris Pump Module
    24301-0007T

    Alaris Pump Module

    • Low Sorbing Set
    Alaris Pump Module set Non-Vented needle-free valve bag access port Low Sorbing 0.2 Micron Filter (1.72 sq. in Low Protein Binding) Roller, Pinch Clamp(s) 1 SmartSite needle-free valve(s) 6" above bonded Texium closed male luer from Texium Closed Male Luer. Not Made with DEHP. 20 Drop L: 115 in L: 292 cm PV: 27 mL Fluid Path Sterile
  11. Extension
    ME1225

    Extension

    • Filtered Set
    • 50 Per case
    Extension set 1.2 Micron Filter (1.6 sq. in Low Protein Binding) Slide Clamp(s) Spin Male Luer Lock. Not Made with DEHP. L: 15 in L: 38 cm PV: 4.8 mL Content Sterile
  12. Extension
    10807851

    Extension

    • Filtered Set
    • 100 Per case
    Extension set 0.2 Micron Filter (1.72 sq. in Low Protein Binding) Pinch Clamp(s) 1 VersaSafe Split Septum Port(s) 6
  1. Page 1 / 4
Filtering
Your selection leads to no items, please widen your search criteria.