1. 2426-0007 / Administration Set
    2426-0007

    Alaris Pump Module

    • Administration Set
    • 20 Per case
    Alaris Pump Module set Check Valve Roller, Slide Clamp(s) 3 SmartSite needle-free valve(s) 6", 74", 90" (1 above pumping segment and 2 below) from 2-piece Male Luer Lock. Not Made with DEHP. 20 Drop L: 126 in L: 320 cm PV: 26 mL Fluid Path Sterile
  2. 10013361T
    10013361T

    Alaris Pump Module

    • Bag Access Set
    Alaris Pump Module set Non-Vented needle-free valve bag access port Check Valve Roller Clamp(s) 2 SmartSite needle-free valve(s) 6", 87" (1 above pumping segment and 1 below) from Texium Closed Male Luer. Not Made with DEHP. 20 Drop L: 118 in L: 298 cm PV: 25 mL Fluid Path Sterile
  3. MS3500 / Secondary Set with Hanger
    MS3500

    Secondary

    • Secondary Administration Set
    • 50 Per case
    Secondary set Roller Clamp(s) Spin Male Luer Lock with hanger. Not Made with DEHP. 20 Drop L: 36 in L: 92 cm PV: 12 mL Fluid Path Sterile
  4. 10013364T / Secondary Set with Bonded Texium
    10013364T

    Secondary

    • Bag Access Set
    Secondary set Non-Vented needle-free valve bag access port Roller Clamp(s) Texium Closed Male Luer with hanger. Not Made with DEHP. 20 Drop L: 32 in L: 81 cm PV: 12 mL Fluid Path Sterile
  5. 82113E / Add on Burette
    82113E

    Gravity

    • Burette Set
    • 20 Per case
    Gravity set 150mL Burette (SmartSite) Roller Clamp(s) Add-on. Not Made with DEHP. L: 22 in L: 56 cm Fluid Path Sterile
  6. 2000E / SmartSite Connector
    2000E

    Connector

    • Connector
    • 100 Per case
    SmartSite Needle-free Connector. Not made with DEHP. PV: 0.11 mL *Labeled for use with low pressure power injectors up to 325 psi and maximum flow rate of 10 mL/second.
  7. MZ1000-07 / MaxZeroConnector
    MZ1000-07

    Connector

    • MaxZero Connector
    • 100 Per case
    MaxZero Zero Reflux IV Connector. Not made with DEHP. PV: 0.19mL *Labeled for use with low pressure power injectors up to 325 psi and maximum flow rate of 10 mL/second.
  8. MZ5302
    MZ5302

    Extension

    • Pressure Rated Extension Set
    • 50 Per case
    Extension set Pressure Rated Minibore 1 Removable MaxZero Needle-free Connector(s) Slide Clamp(s) Spin Male Luer Lock. Not Made with DEHP. L: 7 in L: 18 cm PV: 0.4 mL Content Sterile *Labeled for use with low pressure power injectors up to 325 psi and maximum flow rate of 10 mL/second.
  9. MZ5303
    MZ5303

    Extension

    • Pressure Rated Extension Set
    • 50 Per case
    Extension set pressure rated standard bore, 1 bonded MaxZero needle-free connector, pinch clamp, spin male luer lock. Not Made with DEHP. L: 7 in L: 18 cm PV: 0.5 mL Content Sterile *Labeled for use with low pressure power injectors up to 325 psi and maximum flow rate of 10 mL/second.
  10. Gravity
    10802688

    Gravity

    • Administration Set
    Gravity set Check Valve Roller Clamp(s) 3 SmartSite needle-free valve(s) 6", 36", 41" from 2-piece Male Luer Lock. Not Made with DEHP. 10 Drop L: 107 in L: 272 cm PV: 23 mL Fluid Path Sterile
  11. Closed Vial Access Device
    MV0520

    Vial Access

    • Vial Access
    SmartSite 20mm Closed Vial Access Device. Not made with DEHP
  12. MY8030 / 30mL Bonded Texium Syringe
    MY8030

    Bonded Syringe

    • Syringe
    Needle-Free Syringe with Bonded Texium Closed Male Luer. Not made with DEHP. PV: 30 mL