Brands

  1. Page 1 / 35

Your Selections

  1. Brands

Narrow By

Number of y-sites

Number of Fuses

Number of Connectors

Removable or Bonded Connectors

Close
  1. Alaris Pump Module
    2420-0007

    Alaris Pump Module

    • Administration Set
    • 20 Per case
    Alaris Pump Module set Check Valve Roller Clamp(s) 2 SmartSite needle-free valve(s) 6", 81" (1 above pumping segment and 1 below) from 2-piece Male Luer Lock. DEHP is not part of the material formulation. 20 Drop L: 117 in L: 297 cm PV: 25 mL Fluid Path Sterile
  2. 2426-0007 / Administration Set
    2426-0007

    Alaris Pump Module

    • Administration Set
    • 20 Per case
    Alaris Pump Module set Check Valve Roller, Slide Clamp(s) 3 SmartSite needle-free valve(s) 6", 74", 90" (1 above pumping segment and 2 below) from 2-piece Male Luer Lock. Not Made with DEHP. 20 Drop L: 126 in L: 320 cm PV: 26 mL Fluid Path Sterile
  3. 2000E / SmartSite Connector
    2000E

    Connector

    • Connector
    • 100 Per case
    SmartSite Needle-free Connector. Not made with DEHP. PV: 0.11 mL *Labeled for use with low pressure power injectors up to 325 psi and maximum flow rate of 10 mL/second.
  4. Multi-Fuse Peripheral Extension Set Bi-Fuse
    MZX5306

    Multi-Fuse Peripheral Extension Set Bi-Fuse

    • 50 Per case
    Extension set Standard Bore pressure rated, 1 removable MaxZero needle-free connector, 1 Max Y-Site, 1 white slide clamp, spin male luer lock. Not made with DEHP. L: 8 in L: 20 cm PV: 1.0 mL. Content Sterile.
  5. 11590100 / Alaris Pump Module Set
    11590100

    Alaris Pump Module

    • Administration Set
    • 20 Per case
    Alaris Pump Module set Check Valve Roller Clamp(s) 2 SmartSite needle-free valve(s) 6
  6. Alaris Pump Module
    2477-0007

    Alaris Pump Module

    • Blood Set
    • 10 Per case
    Alaris Pump Module set Non-Vented Blood Set 180 Micron Filter Roller, 2 Slide Clamp(s) 1 SmartSite needle-free valve(s) 65" (below pumping segment) from 2-piece Male Luer Lock. Not Made with DEHP. 15 Drop L: 121 in L: 308 cm PV: 33 mL Fluid Path Sterile
  7. Gravity
    47177E

    Gravity

    • Administration Set
    Gravity set Check Valve Roller Clamp(s) 2 SmartSite needle-free valve(s) 4", 78" from Fixed Male Luer Lock. Not Made with DEHP. 10 Drop L: 104 in L: 264 cm PV: 23 mL Fluid Path Sterile
  8. Gravity
    10053857

    Gravity

    • Administration Set
    Gravity set Check Valve Roller, Slide Clamp(s) 2 SmartSite needle-free valve(s) 7", 74" from 2-piece Male Luer Lock. Not Made with DEHP. 15 Drop L: 101 in L: 257 cm PV: 22 mL Fluid Path Sterile
  9. Gravity
    10802688

    Gravity

    • Administration Set
    Gravity set Check Valve Roller Clamp(s) 3 SmartSite needle-free valve(s) 6", 36", 41" from 2-piece Male Luer Lock. Not Made with DEHP. 10 Drop L: 107 in L: 272 cm PV: 23 mL Fluid Path Sterile
  10. Gravity
    47233E

    Gravity

    • Administration Set
    Gravity set Check Valve Roller Clamp(s) 2 SmartSite needle-free valve(s) 9", 85" from 2-piece Male Luer Lock. Not Made with DEHP. 60 Drop L: 104 in L: 264 cm PV: 18 mL Fluid Path Sterile
  11. 10014917 / Alaris Syringe Module Set
    10014917

    Alaris Syringe Module

    • Pressure Sensing Disc Set
    Alaris Syringe Module set Smallbore Pressure Sensing Disc Slide Clamp(s) Fixed Male Luer Lock. Not Made with DEHP. L: 60 in L: 152 cm PV: 1.7 mL Fluid Path Sterile
  12. Alaris Pump Module
    10015414

    Alaris Pump Module

    • Blood Set
    • 10 Per case
    Alaris Pump Module set Non-Vented Blood Set 180 Micron Filter Roller, 2 Slide Clamp(s) 2-piece Male Luer Lock. 15 Drop L: 126 in L: 318 cm PV: 37 mL Fluid Path Sterile
  1. Page 1 / 35
Filtering